Flows 41 Over Heat 042-700 - Dell 2130cn Service Manual

Hide thumbs Also See for 2130cn:
Table of Contents

Advertisement

Flows 41 Over Heat 042-700

This error occurs when the internal temperature of the printer rises to somewhere
near the predetermined value during a high volume 2-sided print. Although this
error is automatically recovered when the printer's internal temparature falls to a
certain level, it akes a long time before the recovery.
When performing a high volume 2-dided print, divide the job in blocks and allow
as long an interval as possible between them.
If this error code is displayed although you have not performed any large volume 2-
sided printing, follow the following flow.
Checking the error.
Does the error still occur when the
power is turned off and on?
Yes
Replace the PWBA MCU. (Removal 43/
Replacement 18)
No
1 - 79
Chapter 1 Troubleshooting
END