Chapter 3 Removal and Replacement Procedures (RRPs)
Removal 4 PHD Unit (PL4.1.21)
Note: Remove the Tray 1 before working.
Note: Cover the drum of the PHD unit to avoid exposure to light.
1) Remove the Tray 1. (Removal 1)
2) Open the COVER ASSY FRONT (PL1.2.1).
3) Open the TRANSFER ASSY (PL6.1.7).
4) Put the paper on the TRANSFER ASSY
to protect the belt.
Note: When carrying out the work this
procedure, take care not to cover the
left and right of the belt guards with the
paper.