Chapter 3 Removal and Replacement Procedures (RRPs)
Removal 5 KIT FUSER ASSY (PL6.1.97)
1) Open the COVER ASSY FRONT (PL1.2.1).
Note: The FUSER part is very hot. Take added care not to get burned when performing the
service operation.
2) Open the TRANSFER ASSY (PL6.1.7).
3) Pull the LEVER to release the lock.
4) Disengage the connector of the FUSER
ASSY by pulling the right side of the
FUSER ASSY toward you with the LEVER
released.
3 - 13