Flows 78 Crum Id - Dell 2130cn Service Manual

Hide thumbs Also See for 2130cn:
Table of Contents

Advertisement

Flows 78 CRUM ID 093-965

Error and PHD ASSY type check
If an error occurs after turning the
power off and on, is a 2130cn PHD
ASSY is installed in the printer?
Checking after reseating the PHD
ASSY
Reseat the PHD ASSY.
Does the error still occur when the
power is turned off and on?
Checking after replacing the PHD ASSY
Replace the PHD ASSY. (Refer to
Removal 4/ Replacement 50.)
Does the error still occur when the
power is turned off and on?
Replace the PWBA MCU. (Refer to
Removal 43/ Replacement 11.)
No
Yes
No
Yes
No
Yes
Does the error occur after installing a
2130c PHD ASSY and turning the
power off and on?
Yes
END
END
1 - 128
Chapter 1 Troubleshooting
No
END