Chapter 3 Removal and Replacement Procedures (RRPs)
19) Release the ACTUATOR REGI OUT
from the hook on the CHUTE UP
(PL3.2.26), open the ACTUATOR REGI
OUT.
20) Release the three hooks that fix the
SENSOR PHOTO: REGI (PL3.2.13) to the
FEEDER ASSY (PL3.1.98), and remove
the SENSOR PHOTO: REGI.
Note: When carrying out the work this
procedure, it is easier to push the
ACTUATOR.
21) Disengage the connector (P/J232) of
the SENSOR PHOTO: REGI.
3 - 121