6. Operating Environment

6.1 Installation Temperature / Humidity

Installation temperature and humidity on the condition without condensation is as follows.
At operating: 5-32 °C, 15-85%RH (No condensation)
At standby: minus 20-40 °C, 5-85%RH (No condensation)

6.2 Installation Altitude

0 to 3,100m

6.3 Installation Horizontality

Longitudinal levelness of table surface on which the printer is installed:1 degree or under
Lateral levelness of table surface on which the printer is installed

6.4 Ambient Lighting

3,000 Lux or less (without no direct sun beams)

6.5 Storage Temperature of a Toner Cartridge

The guaranteed period of the print cartridge before unpacked is as follows:
Normal conditions: 24 months under 0 to 35°C, 15 to 80% RH.
Harsh conditions: Up to one month under -20 to 0°C and 35 to 40°C, 5 to 15% RH and 80 to 95% RH.
The storage altitude shall be 0 to 3,100m. Can be extended to 0 to 15,000m when shipped by air.
(Provided that the cargo bay is pressurized to 70.9275Kpa or higher.)