Chapter 3 Removal and Replacement Procedures (RRPs)
12) Remove the one screw (silver, with
washer, 6mm) that fixes the grounding
terminal of the HARN ASSY GFI GND
(PL8.2.10), release the HARN ASSY GFI
GND from the GUIDE HARNESS AC
(PL8.2.6).
13) Remove the two screws (silver, tap,
12mm) that fix the BREAKER GFI
(PL8.2.11) to the printer.
14) Pull out the BREAKER GFI, disengage
the three connectors (P/J482, 483, 484).
Remove the BREAKER GFI from the
printer.