CHAPTER 5 PICK UP/FEEDING SYSTEM
3) Loosen the two screws [2] that have
been tightened temporarily, and check
to make sure that the spring provides
tension; then, tighten the screws [2].
At the end, be sure the timing
belt has tension.

9.6.5 Removing the Duplexing Feeding Left Motor

1) Remove the front cover of the duplex
unit.
2) Disconnect the connector [1], and re-
move the two screws [2]; then, detach
the duplex feeding left motor [3].

9.6.6 Removing the Duplex Feeding Right Motor

1) Remove the front cover of the duplex
unit.
2) Disconnect the connector [1], and re-
move the two screws [2]; then, detach
the duplex feeding right motor [3].
5-72 P
COPYRIGHT © 2001 CANON INC.
F05-906-07
[2]
F05-906-08
[2]
F05-906-09
2000 2000 2000 2000
CANON iR5000i/iR6000i REV.0 JUNE 2001
[2]
[1]
[3]
[2]
[1]
[3]
[2]