Precautions When A Problem Occurs - Omron ACCURAX G5 User Manual

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

Precautions When a Problem Occurs

When checking and verifying I/O after a problem has occurred, the driver may suddenly start
to operate or suddenly stop, so always take the following precautions.
You should assure that anything not described in this manual is not possible with this product.
Precautions
Disconnect the wire before checking for cable breakage. Even if you test conduction with the cable
connected, test results may not be accurate due to conduction via bypassing circuit.
If the encoder signal is lost, the motor may run away, or an error may occur. Be sure to disconnect
the motor from the mechanical system before checking the encoder signal.
When measuring the encoder output, perform the measurement based on the SENGND (CN1 pin
13).
When an oscilloscope is used for measurement, it will not be affected by noise if measurements
are performed using the differential between CH1 and CH2.
When performing tests, first check that there are no persons in the vicinity of the equipment, and
that the equipment will not be damaged even if the motor runs away.
Before performing the tests, verify that you can immediately stop the machine using an immediate
stop even if it runs away.
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
11-1 Error Processing
11-3
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kt seriesR88m-k series

Table of Contents