Omron ACCURAX G5 User Manual page 328

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

6-7 Gain Switching Function
GAIN SWITCHING mode = 3: Switching by Torque Command Change Amount
Torque command change amount (angular acceleration and deceleration speed command) is
set in units of 0.05%/166 μs.
If the amount of change fluctuates and the switching time is not met, the switching will be
cancelled.
In the case of switching due to a change amount of 4% over 2 ms, a value of approx. 6 will
apply. (Change of 0.33% per 166 μs.)
Speed command
Torque command
6
Torque change
amount
Gain 1
GAIN SWITCHING mode = 5, 9: Switching by Speed Command or Actual Motor Speed
Pn118, Pn123
Pn117, Pn122
6-28
Pn125
2
1
2
Speed command or actual motor speed
Gain 1
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Pn127
Pn127
Pn127
Pn127
Pn125
Gain 1
Gain 2
Pn126
Pn125
Pn125
Gain 1
2
1
2
Pn118, Pn123
Pn116, Pn121
Gain 1
Pn126

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kt seriesR88m-k series

Table of Contents