Explanation of Set Values
Set
value
0
External scale feedback pulse count direction non-reverse
1
External scale feedback pulse count direction reverse
Pn327
External Feedback Pulse Phase-Z Setting
Setting
0 to 1
range
Explanation of Set Values
Set
value
0
Phase-Z disconnection detection enabled
1
Phase-Z disconnection detection disabled
Pn328
Internal/External Feedback Pulse Error Counter Overflow Level
Setting
27
1 to 2
range
Set the allowable difference (feedback pulse error) between the motor (encoder) position and load
(external scale) position in command units.
Pn329
Internal/External Feedback Pulse Error Counter Reset
Setting
0 to 100
range
The feedback pulse error is reset every time the motor rotates for the amount set by the Internal/
External Feedback Pulse Error Counter Reset (Pn329). This can be used for purposes where
feedback pulse error accumulates due to slippage.
Feedback pulse
error value [command unit]
(absolute value)
Excessive
feedback pulse
error setting
When using feedback pulse error reset, make sure the feedback pulse error reset setting is set to
a proper value. In the case of an extremely small value, it may not function as a protection against
error operations caused by erroneous connection of external scale.
Take sufficient care to ensure safety.
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
−
Unit
Unit
Command unit
Unit
Rotation
Occurrence of excessive
feedback pulse
deviation error
Feedback pulse error reset setting
8-4 Analog Control Parameters
Explanation
Default
0
setting
Explanation
Default
16000
setting
Default
0
setting
Motor rotation
speed [rotation]
Full closing
Power OFF
Yes
and ON
Full closing
Power OFF
Yes
and ON
Full closing
8
Power OFF
Yes
and ON
8-35