8-6 Extended Parameters
If this setting is 0, the level is set to 115% of nominal torque
Internally ther is a limit of 115%, so higher values are limited to 115%
Pn513
Overspeed Detection Level Setting
Setting
0 to 20,000
range
Set the overspeed detection level.
The overspeed detection level setting will be 1.2 times the maximum motor rotation speed if this
parameter is set to 0.
This parameter should normally be set to 0. The setting should be changed only when it is
necessary to reduce the overspeed detection level.
The set value of this parameter is limited to 1.2 times the maximum motor rotation speed.
The detection margin of error for the set value is ±3 r/min for 17 bit absolute encoder and ±36 r/
min for a 20 bit incremental encoder
Pn514
Overrun Limit Setting
Setting
0 to 1,000
range
Set the allowable operating range for the position command input range.
If the set value is exceeded, motor operation range setting protection is generated.
When position command is not input
8
When position command is input
Pn515
Control Input Signal Read Setting
Setting
0 to 3
range
Explanation of Set Values
value
0
1
2
3
8-52
Unit
Unit
Motor
Pn514 Pn514
Motor allowable
operating range
Error generation range
Motor
Pn514
Error generation range
Motor allowable operating range
Unit
Set
0.166ms
0.333ms
1 ms
1.666 ms
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
r/min
setting
Default
0.1 rotation
setting
Load
Error generation range
Load
Position command
Pn514
input range
Error generation range
Default
setting
Explanation
All
Power OFF
0
and ON
Full closing
Position
Power OFF
10
and ON
All
Power OFF
0
Yes
and ON