12-2 Parameter List
620
621
622
623
624
627
631
12
632
633
634
635
637
638
12-32
Parameter
name
External Scale
Phase-Z
Set the external scale phase-Z output width. 0
Expansion Setting
Serial Absolute
Set the phase-Z regeneration position when
External Scale
the serial absolute external scale is used.
Phase-Z Setting
Select the regeneration method of pulse
Phase-AB
Regeneration
outputs OA and OB when an external scale
of phase AB-output type is used.
Method Selection
for External Scale
0
Without signal regeneration
of Phase-AB
Output Type
1
With signal regeneration
Disturbance Torque
Set the compensation gain for disturbance
Compensation Gain
torque.
Disturbance Observer
Set the filter time constant for disturbance
Filter Setting
torque compensation.
Select the warning latch time.
Warning Latch
Hold Time
0
Latch time 10 s
Selection
1
Latch time infinite
Set the load characteristics estimated speed
when realtime autotuning is enabled.
Estimation result is finalized when load
0
Realtime
estimation stabilizes.
Autotuning
For load characteristics change, the estimation
Estimated
1
is made at time constant of approx. 7 minutes.
Speed
Selection
For load characteristics change, the estimation
2
is made at time constant of approx. 4 seconds.
For load characteristics change, the estimation
3
is made at time constant of approx. 2 seconds.
REALTIME
AUTOTUNING
Set the CUSTOMIZATION mode detail for
CUSTOMIZATIO
realtime autotuning.
N mode Setting
Absolute Encoder
Initial Pulse
Set the pulse regeneration speed when the
Regeneration
initial pulse is output.
Speed
Hybrid Vibration
Set the hybrid vibration suppression gain
Suppression Gain
during full closing control.
Hybrid Vibration
Set the hybrid vibration suppression filter
Suppression Filter
time constant during full closing control.
Set the vibration detection threshold.
Vibration
If torque vibration that exceeds this setting is
Detection
detected, the vibration detection warning will
Threshold
occur.
Set the warning detection mask setting.If
Warning Mask
you set the corresponding bit to 1, the
Setting
corresponding warning detection will be
disabled.
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
Explanation
setting
0
0
0
53
0
1
0
1000
0
10
0
0
Power
Setting
supply
Unit
range
OFF to
ON
μs
0 to 400
Yes
28
Pulse
0 to 2
Yes
0 to 1
Yes
-100 to
%
100
0.01
10 to
ms
2,500
0 to 1
Yes
0 to 3
-32,768
to 32,767
1,000 to
r/min
3,000
0 to
0.1/s
30,000
0.01
0 to
ms
6,400
0 to
0.1%
1,000
-32,768
Yes
to 32,767