Pn313
Soft Start Deceleration Time
Setting
0 to 10,000
range
Control the speed by setting acceleration/deceleration to the speed command inside the driver.
A soft start can be set when inputting speed commands of stepping movement or when using
internal speed setting.
Do not set acceleration/deceleration time settings when using the driver in combination with an
external position loop. (Set both Pn312 and Pn313 to 0.)
Internally set
speed
Speed
Acceleration Time
Pn314
S-curve Acceleration/Deceleration Time Setting
Setting
0 to 1,000
range
Set the pseudo-S-curve acceleration/deceleration value to add to the speed command to enable
smooth operation. This is useful for applications where impact may occur due to a large change
in acceleration or deceleration when starting or stopping with linear acceleration or deceleration.
ts
ts
ta
Pn315
Zero Speed Designation Selection
Setting
0 to 3
range
Explanation of Set Values
Set
value
0
Zero speed designation function is disabled.
1
Speed command becomes 0 upon zero speed designation input. (Refer to Figure A)
Speed command becomes 0 upon zero speed designation input, and servo locks with
2
position control when actual speed reaches below Zero Speed Designation Level (Pn316).
(Refer to Figure B)
Servo locks with position control upon zero speed designation input and when speed
3
command reaches below Zero Destination Level (Pn316). (Refer to Figure C)
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
ms/(1,000 r/min)
1,000 r/min
Deceleration time
Unit
ms
1. Basic linear acceleration time and
deceleration time are set by Pn312
and Pn313, respectively.
2. The S-curve time is set by Pn314
(unit: 2 ms) based on the time width
ts
ts
around the point of inflection during
linear acceleration and deceleration.
td
ta: Pn312
Use
td: Pn313
as settings.
ts: Pn314
Unit
8-4 Analog Control Parameters
Default
0
setting
Default
0
setting
ta
td
> ts, and
> ts
2
2
Default
0
setting
Explanation
Speed
Power OFF
and ON
Speed
Power OFF
and ON
8
Speed Torque
Power OFF
and ON
8-29