Omron ACCURAX G5 User Manual page 525

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

Parameter
name
Command
005
Pulse Input
Selection
Command Pulse
Rotation Direction
006
Switching
Selection
COMMAND
007
PULSE mode
Selection
Electronic Gear
008
Integer Setting
Electronic Gear
009
Ratio
Numerator 1
Electronic Gear
010
Ratio
Denominator
Encoder Dividing
011
Numerator
Encoder Output
Direction
012
Switching
Selection
013 No. 1 Torque Limit Set the No. 1 limit value for the output torque of the motor. 500
Error Counter
014
Overflow Level
Operation
Switch when
015
Using Absolute
Encoder
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Explanation
Select the command pulse input.
0
Photocoupler input
1
Input for line driver only
Set the command pulse count direction.
0
Forward direction
1
Reverse direction
Set the COMMAND PULSE mode.
90° phase difference (A/B) signal inputs
0
for rotation in forward direction
Forward pulse/reverse pulse for rotation
1
in forward direction
90° phase difference (A/B) signal inputs
2
for reverse rotation
Feed pulse/direction signal for rotation
3
in reverse direction
Set the number of command pulses per
motor rotation.
Set the electronic gear ratio.
If Pn009 = 0, the encoder resolution is set as
the numerator.
Electronic gear ratio numerator 1 (Pn009)
Electronic gear ratio denominator (Pn010)
Set the number of phase A and phase B
output pulses, respectively per motor rotation.
Select the phase B logic for pulse
regeneration output and the output source.
Phase B logic: Not reversed
0
Output source: Encoder
Phase B logic: Reversed
1
Output source: Encoder
Phase B logic: Not reversed
2
Output source: External scale
Phase B logic: Reversed
3
Output source: External scale
Set the range of the error counter overflow
level. Detection of error counter overflow
level error will be disabled if the set value is 0.
Select the absolute encoder usage method.
0
Used as absolute encoder.
1
Used as an incremental encoder.
Used as absolute encoder.
2
(Multi-rotation counter overflows are
ignored.)
12-2 Parameter List
Default
Setting
Unit
setting
range
0
0 to 1
0
0 to 1
1
0 to 3
20
10000
Pulse
0 to 2
30
0
0 to 2
30
10000
1 to 2
0 to
2500
P/r
262,144
0
0 to 3
%
0 to 500
Command
27
480000
0 to 2
unit
1
0 to 2
12-13
Power
supply
OFF to
ON
Yes
Yes
Yes
Yes
Yes
12
Yes
Yes

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kt seriesR88m-k series

Table of Contents