8-7 Special Parameters
If torque vibration that exceeds this setting is detected, the vibration detection warning will occur.
Pn638
Warning Mask Setting
Setting
−32,768 to 32,767
range
Set the warning detection mask setting. See chapter 11-2 for detail of the bits.
If you set the corresponding bit to 1, the corresponding warning detection will be disabled.
8
8-64
−
Unit
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Default
Power OFF
0
setting
and ON
All
Yes