Omron ACCURAX G5 User Manual page 411

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

Pn439
Brake Release Speed Setting
Setting
30 to 3,000
range
Pn440
Warning Output Selection 1
Setting
0 to 10
range
Explanation of Set Values
Set
value
0
No
1
Overload warning
2
Excessive regeneration warning
3
Battery warning
4
Fan warning
5
Encoder communications warning
8
Encoder overheating warning
9
External scale error warning
10
External scale communications error warning
Do not set it to a value other than a number 0 to 5, and 8 to 10.
Refer to "11-2 Warning List" (P.11-5) for more information on settings.
Pn441
Warning Output Selection 2
Setting
0 to 7
range
The set values for this parameter are same as Warning Output Selection 1 (Pn440).
Pn442
Positioning Completion Range 2
Setting
0 to 262,144
range
Set the positioning completion range.
The set values for this parameter are same as Positioning Completion Range 1 (Pn431).
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Unit
r/min
Pn438 set value
Released (ON)
*1
t1
Motor rotation speed
Pn439 set value
Pn438 set value
Released (ON)
Engaged (OFF)
*1
t1
Motor rotation speed
Pn439 set value
Unit
Unit
Unit
Command unit
8-5 Interface Monitor Setting Parameters
Default
setting
Engaged (OFF)
When the motor
takes longer than
Pn438 ms to reach
Pn439 rpm
When the motor takes
less than Pn438 ms to
reach Pn439 rpm
Default
setting
Explanation
Default
setting
Default
setting
All
Power OFF
30
Yes
and ON
All
Power OFF
0
and ON
All
Power OFF
0
and ON
Full closing
Position
Power OFF
10
and ON
8-45
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kt seriesR88m-k series

Table of Contents