External Feedback Pulse Type Selection (Pn323, Pn326)
Set the external scale output type and direction.
Parameter
number
External
Feedback Pulse
Type Selection
Pn323
External
Feedback Pulse
Direction
Pn326
Switching
<
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Parameter name
Select the type of the external scale
to be used.
Set
value
0
1
2
If the count directions of the external
scale feedback pulse and the
encoder total feedback pulses do not
match, set the reversal of the
external scale feedback pulse
direction.
0: Not reversed, 1: Reversed
5-6 Full Closing Control
Explanation
External scale type
90 phase difference output type
Serial communications (Incremental
encoder specifications)
Serial communications (Absolute
encoder specifications)
Setting
Unit
range
−
0 to 3
−
0 to 1
5-29