Omron ACCURAX G5 User Manual page 507

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

Symptom
Probable cause
The motor is
The machine and the motor
producing unusual
are resonating.
noises or the
machine is
vibrating.
(Continued from
previous page)
Vibration is
Inductive noise is occurring. Check whether the driver control
occurring at the
same frequency as
the power supply.
The position is
There is an error in the
misaligned.
coupling of the mechanical
(Position
system and the Servomotor.
misalignment
Noise is entering the error
occurs without an
counter reset (ECRST).
alarm being
output.)
The gain is wrong.
The load inertia is large.
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Items to check
Check whether the machine is
resonating.
signal lines are too long.
Check whether the control signal
lines and power supply lines are not
bound together.
Check whether the coupling of the
mechanical system and the
Servomotor is misaligned.
Check whether the control signal
lines and power supply lines are not
bound together.
Inspect the following.
· Is the load too large?
· Is the motor rotation speed too
high?
11-4 Troubleshooting
Measures
· Readjust the torque
command filter time
constant.
· If there is resonance, set
the Notch Filter 1
Frequency (Pn201), Notch
Filter 1 Width (Pn202), and
Notch Filter 1 Depth
(Pn203).
Shorten the control signal
lines.
· Separate control signal
lines from power supply
lines.
· Use a low-impedance
power supply for control
signals.
Correct the coupling between
the mechanical system and
the Servomotor.
Separate the control signal
lines from the power lines or
take other measures against
noise.
Perform manual tuning.
· Adjust the gain.
· Review the load
conditions, and replace the
Servomotor and Servo
Drive with appropriate
models.