Omron ACCURAX G5 User Manual page 306

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

6-1 Anti-vibration Control
4. Set the Vibration Filter Selection (Pn213).
Vibration filters 1 to 4 can be switched according to the conditions of the machine vibration.
Set value
0
1
2
3
Vibration Filter Selection (Pn213) is a parameter that becomes effective when the power is
turned on. After setting this parameter, turn OFF the control power supply and then turn it ON
again.
6
6-6
Vibration filter 1 and 2 enabled
Switching by external input (DFSEL1)
Open: Vibration filter 1 or 3 enabled
Shorted: Vibration filter 2 or 4 enabled
Switching by external input (DFSEL1, DFSEL2)
When DFSEL1 and DFSEL2 are both open: Vibration filter 1 enabled
When DFSEL1 is shorted and DFSEL2 is open: Vibration filter 2
enabled
When DFSEL1 is open and DFSEL2 is shorted: Vibration filter 3
enabled
When DFSEL1 and DFSEL2 are both shorted: Vibration filter 4
enabled
Switching with command direction
Forward direction: Vibration filter 1 or 3 enabled
Reverse direction: Vibration filter 2 or 4 enabled