Omron ACCURAX G5 User Manual page 457

Accurax g5 servo system with analogue/pulse control; servo drives/servomotors
Hide thumbs Also See for ACCURAX G5:
Table of Contents

Advertisement

Analog Input Automatic Offset Adjustment
This performs automatic adjustment on the Offset Values (Pn422, Pn425 and Pn428) of
Analog Inputs 1 to 3 (AI1 to AI3).
Do not perform this operation if a position loop has been configured with the host system.
1. Execute automatic offset adjustment
Key
operation
2. Returning to AUXILIARY FUNCTION mode display
Key
operation
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Display example
Press the
OFFSET ADJUSTMENT mode from the alarm clear display in
or
the AUXILIARY FUNCTION mode.
or
Press the
ADJUSTMENT mode of the analog input number to be set.
or
or
Press and hold the
or
or
The bar indicator will increase.
Automatic offset adjustment will start.
This indicates a normal completion.
could not be performed. Set a valid CONTROL mode or make
the setting so that the offset value does not exceed the range for
the Speed Command Offset Adjustment (Pn52), and then
execute the procedure again.
Display example
Press the
or
or
9-4 Setting the Mode
Explanation
key to display the ANALOG INPUT AUTOMATIC
key to enter the AUTOMATIC OFFSET
key for 5 seconds or longer until
is displayed.
will be displayed if the automatic offset adjustment
Explanation
key to return to AUXILIARY FUNCTION mode.
9
9-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88d-kt seriesR88m-k series

Table of Contents