3-1 Driver Specifications
Pin
Symbol
number
WARN2
WARN2COM
P-CMD
P-
CMDCOM
V-LIMIT
V-
LIMITCOM
ALM-ATB
ALM-
3
ATBCOM
V-CMD
V-
CMDCOM
You cannot change the allocation for servo alarm output (/ALM). (The allocation is fixed.)
The number in brackets indicates the pin number (allocation) at default setting. (The allocations
vary according to each CONTROL mode.)
3-22
Name
Warning output 2
This output turns ON according to the
setting condition of Warning Output
Selection 1 (Pn440).
Position command
This output turns ON when a positioning
status output
command is input.
Speed limiting output
This turns ON during torque control or
speed limit status.
Alarm clear attribute
This output turns ON when an alarm
output
occurs or the alarm can be cleared.
Speed command status
This output turns ON during speed
output
control or when a speed command is
input.
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Function and interface
CONTROL mode
Full
Position Speed Torque
closing