4-3 Wiring Conforming to EMC Directives
Cable Details
Symbol
(1)
(2)
(3)
(4)
(5)
(6)
(7)
4
(8)
For operations, if no-fuse breakers are installed at the top and the power supply line is wired from
the lower duct, use metal tubes for wiring or make sure that there is adequate distance between
the input lines and the internal wiring. If input and output lines are wired together, noise resistance
will decrease.
The noise filter must be installed as close as possible to the entrance of the control panel. Wire
as shown at the left in the following illustration.
AC input
Ground
Use twisted-pair cables for the power supply cables, or bind the cables.
Separate power supply lines and signal lines when wiring.
4-24
Supplies from
Connects to
AC power supply Noise filter
Noise filter
Servo Drive
Servo Drive
Servomotor
Servo Drive
Servomotor
Switch box
Servo Drive
Frame ground
Noise filter
Frame ground
Noise filter
AC power supply Switch box
Separate the input and output.
1
4
NF
2
5
3
6
E
Twisted-pair process
Servo Drive
L1C
L2C
Accurax G5 AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Cable name
Length
Power supply
2 m
line
Power supply
2 m
line
20 m −
Power cable
Encoder
20 m −
cable
I/O cable
2 m
1.5
FG line
m
1.5
FG line
m
Power supply
1.5
line
m
The effect of the noise filter is small.
AC output
AC input
Ground
AC output
Comment
Shielded
3-phase or single
No
phase
No
Yes
Yes
Optional
No
No
No
1
4
NF
2
5
3
6
E
Bound cables
Servo Drive
L1
L2
L3
Binding
Ferrite
No
Optional
Optional
Optional
Optional
No
No
No