Central management
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Device health data upload is enabled by default. To enable or disable:
n
To enable:
(config)> monitoring devicehealth enable true
(config)>
n
To disable:
(config)> monitoring devicehealth enable false
(config)>
4. The interval between health sample uploads is set to 60 minutes by default. To change:
(config)> monitoring devicehealth interval value
(config)>
where value is one of 1, 5, 15, 30, or 60, and represents the number of minutes between
uploads of health sample data.
5. By default, the device will only report health metrics values to Digi Remote Manager that have
changed health metrics were last uploaded. This is useful to reduce the bandwidth used to
report health metrics. This is useful to reduce the bandwidth used to report health metrics.
Even if enabled, all metrics are uploaded once every hour.
To disable:
(config)> monitoring devicehealth only_send_deltas false
(config)>
When disabled, all metrics are uploaded every Health sample interval.
6. (Optional) Tuning parameters allow to you configure what data are uploaded to the Digi
Remote Manager. By default, all tuning parameters are enabled.
To view a list of all available tuning parameters, use the show command:
(config)> show monitoring devicehealth tuning
all
cellular
eth
IX20 User Guide
Configure your device for Digi Remote Manager support
rx
bytes
enable true
tx
bytes
enable true
rx
bytes
enable true
tx
70