Interfaces
a. Type ... to return to the root of the configuration:
(config network interface my_wan surelink actions 0)> ...
(config)>
b. Set the test interval between connectivity tests:
(config)> network interface my_wan surelink interval value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set interval to ten minutes, enter either 10m or 600s:
(config)> network interface my_wan surelink interval 600s
(config)>
The default is 15m.
c. If more than one test target is configured, set the success condition:
(config)> network interface my_wan surelink success_condition value
(config)>
where value is either:
n
n
d. Set the number of times that the test must pass after failure, before the interface is
determined to be working and is reinstated.
(config)> network interface my_wan surelink pass_threshold int
(config)>
The default is 1.
e. Set the amount of time that the device should wait for a response to a test failure before
considering it to have failed:
(config)> network interface my_wan surelink timeout value
(config)>
where value is any number of weeks, days, hours, minutes, or seconds, and takes the
format number{w|d|h|m|s}.
For example, to set timeout to ten minutes, enter either 10m or 600s:
(config)> network interface my_wan surelink timeout 600s
(config)>
The default is 15s.
f. Set the amount of time to wait while the device is starting before SureLink testing begins.
This setting is bypassed when the interface is determined to be up.
IX20 User Guide
one: Only one test needs to pass for Surelink to consider an interface to be up.
all: All tests need to pass for SureLink to consider the interface to be up.
Wide Area Networks (WANs)
115