Digi IX20W-PR User Manual page 291

Table of Contents

Advertisement

Serial port
1. Select the device in Remote Manager and click Actions > Open Console, or log into the IX20
local command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. The serial port is enabled by default. To disable:
(config)> serial port1 enable false
(config)>
4. Set the mode:
(config)> serial port1 mode modbus
(config)>
5. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
6. 1. Set the baud rate used by the device to which you want to connect:
(config)>serial port1 baudrate rate
(config)>
2. Set the number of data bits used by the device to which you want to connect:
(config)>serial port1 databits bits
(config)>
3. Set the type of parity used by the device to which you want to connect:
(config)>serial port1 parity parity
(config)>
Allowed values are:
even
n
odd
n
none
n
The default is none.
4. Set the stop bits used by the device to which you want to connect:
(config)>serial port1 stopbits bits
(config)>
IX20 User Guide
Configure Modbus mode
291

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ix20Ix20wIx20-pr

Table of Contents