Serial port
6. Data encryption is enabled by default. To disable:
(config)> service realport encryption false
(config)>
7. (Optional) Configure authentication.
(config)> service realport auth value
(config)>
where value is one of:
n
none: Do not use authentication. This is the default.
n
shared_secret_sha256: You must also define the authentication password to ensure
secure communication. Leave this field blank to disable authentication.
(config)> service realport auth shared_secret_sha256 value
(config)
where value is the authentication password.
8. Exclusive mode is disabled by default. This mode ensures that any connection from an
IP address is closed when opening a new connection from the same IP address. To enable:
(config)> service realport exclusive true
(config)
9. Use RealPort keepalive to send RealPort keepalive packets. This is enabled by default. To
disable:
(config)> service realport realport_keepalive false
(config)>
10. TCP port keepalive to send TCP keepalive packets is disabled by default. To enable:
(config)> service realport tcp_keepalive true
(config)>
11. Device initiated connections allow users to remotely connect to serial devices as if they had a
native COM/TTYport on their PC. This is disabled by default. To enable:
(config)> service realport device_initiated_enable true
(config)>
12. Save the configuration and apply the change
(config)> save
Configuration saved.
>
13. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection