Checking Hydraulic Oil - MacDon M2170 Operator's Manual

Windrower
Hide thumbs Also See for M2170:
Table of Contents

Advertisement

3. Place a container under filter (A) to catch spilled fluid.
4. Turn drain valve (C) by hand 1 1/2 to 2 turns
counterclockwise until draining occurs.
5. Drain the filter sump of water and sediment until clear fuel
is visible.
6. Turn the valve clockwise to close the drain.
7. Dispose of fluid safely.
8. Close the hood. For instructions, refer to
Hood, page
363.

5.7.3 Checking Hydraulic Oil

The hydraulic system will not work correctly if the hydraulic oil level is too low or too high. It is extremely important to
avoid contamination of the hydraulic system when service and regular maintenance is performed.
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operator's seat for any reason.
WARNING
Do NOT inspect the hydraulic system for leaks using a part of your body. High-pressure fluid escaping through a pinhole
leak can penetrate the skin, causing serious injury.
1. Park the windrower on a level surface.
2. Lower the header fully.
3. Lower the reel fully.
4. Shut down the engine, and remove the key from the ignition.
262170
MAINTENANCE AND SERVICING
5.3.2 Closing
Figure 5.62: Fuel System
A - Primary Fuel Filter
B - Water in Fuel (WIF) Sensor
C - Drain Valve
398
A
C
B
Revision A