MacDon M2170 Operator's Manual page 618

Windrower
Hide thumbs Also See for M2170:
Table of Contents

Advertisement

J1939
J1939
Telltale
SPN
FMI
Check
3031
3
Engine
Check
3031
4
Engine
Check
3031
9
Engine
Check
3031
11
Engine
Check
3031
13
Engine
Check
3216
2
Engine
Check
3216
4
Engine
Check
3216
9
Engine
Check
3216
10
Engine
Check
3216
13
Engine
Check
3216
16
Engine
Check
3216
20
Engine
Check
3216
21
Engine
Check
3218
2
Engine
Check
3226
2
Engine
Check
3226
4
Engine
262170
REFERENCE
Cummins
Lamp
Fault Code
Aftertreatment 1 Diesel
Exhaust Fluid Tank
Amber
1678
Temperature
Aftertreatment 1 Diesel
Exhaust Fluid Tank
None
6559
Temperature
Aftertreatment 1 Diesel
Exhaust Fluid Tank
4572
Amber
Temperature
Aftertreatment 1 Diesel
Exhaust Fluid Tank
Amber
4737
Temperature
Aftertreatment 1 Diesel
Exhaust Fluid Tank
Amber
4731
Temperature
Aftertreatment 1
Amber
3228
Intake NOx
Aftertreatment 1
Amber
1885
Intake NOx
Aftertreatment 1
Amber
3232
Intake NOx
Aftertreatment 1
None
6621
Intake NOx
Aftertreatment 1
Amber
3718
Intake NOx
Aftertreatment 1
Amber
3726
Intake NOx
Aftertreatment 1
None
6458
Intake NOx
Aftertreatment 1
None
6459
Intake NOx
Aftertreatment 1 Intake
3682
Amber
Gas Sensor Power Status
Aftertreatment 1
None
6464
Outlet NOx
Aftertreatment Outlet
None
6521
NOx Sensor Circuits
594
J1939_SPN
Description
Aftertreatment 1 Diesel Exhaust
Fluid Tank Temperature Sensor -
Voltage above normal, or shorted
to high source
Aftertreatment 1 Diesel Exhaust
Fluid Tank Temperature Sensor -
Voltage below normal, or shorted
to low source
Aftertreatment 1 Diesel Exhaust
Fluid Tank Temperature -
Abnormal Update Rate
Aftertreatment 1 Diesel Exhaust
Fluid Tank Temperature - Root
Cause Not Known
Aftertreatment 1 Diesel Exhaust
Fluid Tank Temperature Sensor -
Out of Calibration
Aftertreatment 1 Intake NOx
Sensor - Data is erratic,
intermittent, or incorrect
Aftertreatment 1 Intake NOx
Sensor Circuit - Voltage below
normal, or shorted to low source
Aftertreatment 1 Intake NOx
Sensor - Abnormal update rate
Aftertreatment 1 Intake NOx
Sensor - Abnormal rate of change
Aftertreatment 1 Intake NOx - Out
of Calibration
Aftertreatment 1 Intake NOx -
Data valid but above normal
operating range - Moderately
Severe Level
Aftertreatment 1 Intake NOx
Sensor - Data not Rational -
Drifted High
Aftertreatment 1 Intake NOx
Sensor - Data not Rational -
Drifted High
Aftertreatment 1 Intake NOx
Sensor Power Supply - Data is
erratic, intermittent, or incorrect
Aftertreatment 1 Outlet NOx
Sensor - Data not Rational -
Drifted High
Aftertreatment Outlet NOx Sensor
Circuit- Voltage below normal or
shorted to low source
Detail
Revision A

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2260

Table of Contents