MacDon M2170 Operator's Manual page 625

Windrower
Hide thumbs Also See for M2170:
Table of Contents

Advertisement

J1939
J1939
Telltale
SPN
FMI
Check
3936
7
Engine
Stop
3936
14
Engine
Check
3936
15
Engine
Check
4094
31
Engine
Check
4096
31
Engine
Check
4185
31
Engine
Check
4186
31
Engine
Check
4187
31
Engine
Check
4188
31
Engine
Check
4223
31
Engine
Check
4334
2
Engine
Check
4334
3
Engine
Check
4334
4
Engine
Check
4334
16
Engine
262170
REFERENCE
Cummins
Lamp
Fault Code
Aftertreatment 1 Diesel
None
6265
Particulate Filter System
Aftertreatment Diesel
4584
Red
Particulate Filter System
Aftertreatment Diesel
Amber
1981
Particulate Filter System
NOx limits exceeded due
to Insufficient Diesel
Amber
3543
Exhaust Fluid Quality
NOx limits exceeded due
Amber
3547
to Empty Diesel Exhaust
Fluid Tank
Overspeed Shutdown
Amber
1427
Relay Driver
Low Oil Pressure
1428
Amber
Shutdown Relay Driver
High Engine Temperature
1429
Amber
Shutdown Relay Driver
Pre-Low Oil Pressure
1431
Amber
Indicator Relay Driver
Pre-High Engine
Temperature Warning
1432
Amber
Relay Driver
Aftertreatment 1 Diesel
3596
Amber
Exhaust Fluid Doser
Absolute Pressure
Aftertreatment 1 Diesel
3571
Amber
Exhaust Fluid Doser
Absolute Pressure
Aftertreatment 1 Diesel
3572
Amber
Exhaust Fluid Doser
Absolute Pressure
Aftertreatment 1 Diesel
3575
Amber
Exhaust Fluid Doser
Absolute Pressure
601
J1939_SPN
Description
Aftertreatment 1 Diesel
Particulate Filter System -
Mechanical system not
responding or out of adjustment
Aftertreatment Diesel Particulate
Filter System - Special Instructions
Aftertreatment 1 Diesel
Particulate Filter System - Data
valid but above normal operating
range - Level
NOx limits exceeded due to
Insufficient Reagent Quality -
Condition Exists
Aftertreatment Diesel Exhaust
Fluid Tank Empty - Condition
Exists
Overspeed Shutdown Relay Driver
Diagnostic has detected an error -
Condition Exists
Low Oil Pressure (LOP) Shutdown
Relay Driver Diagnostic has
detected an error - Condition
Exists
High Engine Temperature (HET)
Shutdown Relay Driver Diagnostic
has detected an error - Condition
Exists
Pre-Low Oil Pressure Warning
Relay Driver Diagnostic has
detected an error -
Condition exists
Pre-High Engine Temperature
Warning Relay Driver Diagnostic
has detected an error -
Condition exists
Aftertreatment 1 Diesel Exhaust
Fluid Pressure Sensor - Data is
erratic, intermittent, or incorrect
Aftertreatment 1 Diesel Exhaust
Fluid Pressure Sensor - Voltage
above normal, or shorted to high
source
Aftertreatment 1 Diesel Exhaust
Fluid Pressure Sensor - Voltage
below normal, or shorted to
low source
Aftertreatment 1 Diesel Exhaust
Fluid Pressure Sensor - Data valid
but above normal operating range
Detail
Revision A

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2260

Table of Contents