MacDon M2170 Operator's Manual page 627

Windrower
Hide thumbs Also See for M2170:
Table of Contents

Advertisement

J1939
J1939
Telltale
SPN
FMI
Check
4360
3
Engine
Check
4360
4
Engine
Check
4360
15
Engine
Stop
4360
16
Engine
Stop
4363
0
Engine
Check
4363
2
Engine
Check
4363
3
Engine
Check
4363
4
Engine
Stop
4363
16
Engine
Check
4364
17
Engine
Check
4364
18
Engine
Check
4376
3
Engine
262170
REFERENCE
Cummins
Lamp
Fault Code
Aftertreatment 1 SCR
Catalyst Intake Gas
Amber
3142
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
3143
Amber
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
None
3164
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
3231
Red
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
Red
3165
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
Amber
3148
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
None
6569
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
None
6571
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
3235
Red
Temperature
Aftertreatment 1 SCR
None
6517
Conversion Efficiency
Aftertreatment 1 SCR
Amber
3582
Conversion Efficiency
Aftertreatment 1 Diesel
3577
Amber
Exhaust Fluid Return Valve
603
J1939_SPN
Description
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit -
Voltage above normal, or shorted
to high source
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit -
Voltage below normal, or shorted
to low source
Aftertreatment 1 SCR Intake
Temperature - Data valid but
above normal operating range -
Least Severe
Aftertreatment 1 SCR Intake
Temperature - Data valid but
above normal operating range -
Moderately Severe Level
Aftertreatment 1 SCR Outlet
Temperature - Data valid but
above normal operational range -
Most Severe
Aftertreatment 1 SCR Outlet
Temperature Sensor - Data is
erratic, intermittent, or incorrect
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit -
Voltage above normal, or shorted
to high source
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit -
Voltage below normal, or shorted
to low source
Aftertreatment 1 SCR Outlet
Temperature - Data valid but
above normal operating range -
Moderately Severe Level
Aftertreatment SCR Catalyst
Conversion Efficiency - Data valid
but below normal operating range
- Moderately Severe Level
Aftertreatment SCR Catalyst
Conversion Efficiency - Data valid
but below normal operating range
- Moderately Severe Level
Aftertreatment Diesel Exhaust
Fluid Return Valve - Voltage
above normal, or shorted to high
source
Detail
Revision A

Advertisement

Table of Contents
loading

This manual is also suitable for:

M2260

Table of Contents