J1939
J1939
Telltale
SPN
FMI
Stop
630
12
Engine
Check
633
31
Engine
Check
639
9
Engine
Check
639
13
Engine
Stop
640
14
Engine
Check
641
7
Engine
Check
641
9
Engine
Check
641
11
Engine
Stop
641
12
Engine
Stop
641
13
Engine
Check
641
15
Engine
Stop
641
31
Engine
Check
647
3
Engine
Check
647
4
Engine
Check
651
5
Engine
Check
652
5
Engine
262170
REFERENCE
Cummins
Lamp
Fault Code
Engine Control Module
Red
3697
Calibration Memory
Engine Fuel Actuator 1
2311
Amber
Control Command
J1939 Network #1,
Primary Vehicle Network
Amber
285
(previously SAE J1939
Data Link)
J1939 Network #1,
Primary Vehicle Network
Amber
286
(previously SAE J1939
Data Link)
Engine External Protection
599
Red
Input
Engine Variable Geometry
Amber
2387
Turbocharger Actuator #1
Engine Variable Geometry
1894
Amber
Turbocharger Actuator #1
Engine Variable Geometry
Amber
2198
Turbocharger Actuator #1
Engine Variable Geometry
Red
2634
Turbocharger Actuator #1
Engine Variable Geometry
2449
Red
Turbocharger Actuator #1
Engine Variable Geometry
None
1976
Turbocharger Actuator #1
Engine Variable Geometry
2635
Red
Turbocharger Actuator #1
Engine Fan Clutch 1
None
6263
Output Device Driver
Engine Fan Clutch 1
None
6264
Output Device Driver
Engine Injector
Amber
322
Cylinder #01
Engine Injector
331
Amber
Cylinder #02
587
J1939_SPN
Description
Engine Control Module
Calibration Memory - Bad
intelligent device or component
Electronic Fuel Injection Control
Valve Circuit - Condition Exists
SAE J1939 Multiplexing PGN
Timeout Error - Abnormal
update rate
SAE J1939 Multiplexing
Configuration Error - Out of
Calibration
Auxiliary Commanded Dual
Output Shutdown - Special
Instructions
VGT Actuator Driver Circuit
(Motor) - Mechanical system not
responding or out of adjustment
VGT Actuator Driver Circuit -
Abnormal update rate
VGT Actuator Driver Circuit - Root
Cause Not Known
VGT Actuator Controller - Bad
intelligent device or component
VGT Actuator Controller - Out of
Calibration
VGT Actuator Driver Over
Temperature (Calculated) - Data
valid but above normal
operational range - Least Severe
Level
VGT Actuator Driver Circuit -
Condition exists
Fan Control Circuit - Voltage
above normal, or shorted to
high source
Fan Control Circuit - Voltage
below normal, or shorted to
low source
Injector Solenoid Driver Cylinder 1
Circuit - Current below normal or
open circuit
Injector Solenoid Driver Cylinder 2
Circuit - Current below normal or
open circuit
Detail
Revision A