VeriPHY Cable Diagnostics

This section is used for running the VeriPHY Cable Diagnostics for 10/100 and 1G copper ports.
Web GUI: Diagnostics > VeriPHY
Figure 6-4
Copper Link Test Cable Status Diagnostics
:
Press Start to run the diagnostics. This will take approximately 5 seconds. If all ports are selected,
this can take approximately 15 seconds. When completed, the page refreshes automatically, and you
can view the cable diagnostics results in the cable status table.
Note that VeriPHY is only accurate for cables of length 7 — 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a
10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY is complete
Table 6-3: Copper Link Test Cable Diagnostics Parameters
Port
Cable Status
299
The port where the Cable Diagnostics is requested.
"Port": Port number.
"Pair": The status of the cable pair.
OK - Correctly terminated pair
Open - Open pair
Short - Shorted pair
Short A - Cross-pair short to pair A
Short B - Cross-pair short to pair B
Short C - Cross-pair short to pair C
Short D - Cross-pair short to pair D