Link Event Configuration For Selected Port - FibroLAN Falcon-RX/812/G/A User Manual

Table of Contents

Advertisement

Falcon R-Class | User Guide
performance testing. Enabling the loopback support will allow the DTE to
execute the remote loopback command that helps in the fault detection.
Link Monitor
Controls whether the Link Monitor support is enabled for the switch port.
Support
On enabling the Link Monitor support, the DTE supports event notification
that permits the inclusion of diagnostic information.
MIB Retrieval
Controls whether the MIB Retrieval Support is enabled for the switch port.
Support
On enabling the MIB retrieval support, the DTE supports polling of various
Link OAM based MIB variables' contents.
Loopback
If the Loopback support is enabled, enabling this field will start a loopback
Operation
operation for the port.

Link Event Configuration for selected Port

This section allows the user to inspect the current Link OAM Link Event configurations and change
them as well.
Web GUI: Configuration > Link OAM > Events Settings
Figure 4-170: Link Event Configuration for selected port
Table 4-162: Link Event Configuration for selected port Parameters
Port
The switch port number.
Event Name
Name of the Link Event which is being configured.
Error Window
Represents the window period in the order of 1 sec for the observation of
various link events.
Error Threshold
Represents the threshold value for the window period for the appropriate
Link event so as to notify the peer of this error.
Error Frame Event The Errored Frame Event counts the number of errored frames detected
during the specified period. The period is specified by a time interval
(Window in order of 1 sec). This event is generated if the errored frame count
is equal to or greater than the specified threshold for that period (Period
Threshold).
Errored frames are frames that had transmission errors as detected at the
Media Access Control sublayer. Error Window for 'Error Frame Event' must
be an integer value between 1-60 and its default value is '1'. Whereas Error
Threshold must be between 0-0xffffffff and its default value is '0'.
Symbol Period
Controls whether the MIB Retrieval Support is enabled for the switch port.
Error Event
On enabling the MIB retrieval support, the DTE supports polling of various
Link OAM based MIB variables' contents.
237