FibroLAN Falcon-RX/812/G/A User Manual page 166

Table of Contents

Advertisement

Falcon R-Class | User Guide
Note: After applying the Clock configuration hit the button with the clock instance number to
continue to the instance detailed configuration
Table 4-107: PTP Clock Configuration Parameters (for both above displays)
Delete
Clock Instance
HW Domain
Device Type
Profile
Clock Description
Buttons
166
Check this box and click on Save to delete the clock instance.
Indicates the Instance of a particular Clock Instance [0...3]. Click on the
Clock Instance number to edit the Clock details.
Indicates the HW clock domain used by the clock.
Indicates the Type of the Clock Instance. There are five Device Types.
1. Ord-Bound – clock's Device Type is Ordinary-Boundary Clock.
2. P2p Transp – clock's Device Type is Peer to Peer Transparent Clock.
3. E2e Transp – clock's Device Type is End to End Transparent Clock.
4. Master Only – clock's Device Type is Master Only.
5. Slave Only – clock's Device Type is Slave Only.
Definitions:
Master & Slave clock: has only one physical port to the network and can
be implemented as a master or slave clock. The OC sends and receive PTP
messages. It supports the synchronization mechanism.
Boundary clock: has multiple physical ports to the network and can be
used as an intermediate stage/device. The BC performs the functionality
of the Ordinary clock and can be connected to multiple sub-networks:
normally it is synchronized to one Master reference clock and provides
synchronization to various clients.
End to End Transparent clock: there are multiple ports and do not behave
or perform a Master and slave relationship. These ports forward all PTP
messages and correct the timing.
Peer to peer Transparent clock: there are multiple ports and do not
behave or perform a Master and slave relationship. Each port supports the
Pdelay mechanism
Indicates the profile used by the clock.
User defined free text (64 characters)
Add New PTP Clock: Hit to add a PTP clock instance entry to the table.
Apply: Hit to apply the clock instance settings to the running-config.
Reset: Hit to reset the new clock instance parameters to previous values.
PTP Status: Click on it to go to PTP Status display.
Sync Center config: Click on it to go to SyncCenter config. display