Detailed Link Oam Statistics For Selected Port - FibroLAN Falcon-RX/812/G/A User Manual

Table of Contents

Advertisement

Falcon R-Class | User Guide
Seconds Summary
The Errored Frame Seconds Summary Event TLV counts the number of
Event
errored frame seconds that occurred during the specified period. The period
is specified by a time interval. This event is generated if the number of
errored frame seconds is equal to or greater than the specified threshold for
that period.
An errored frame second is a one second interval wherein at least one frame
error was detected. Errored frames are frames that had transmission errors
as detected at the Media Access Control sublayer. Error Window for 'Seconds
Summary Event' must be an integer value between 10-900 and its default
value is '60'. Whereas Error Threshold must be between 0-0xffff and its
default value is '1'.

Detailed Link OAM Statistics for selected port

This section provides detailed OAM traffic statistics for a specific switch port. Use the port select box
to select which switch port details to display.
The displayed counters represent the total number of OAM frames received and transmitted for the
selected port. Discontinuities of these counters can occur at re-initialization of the management
system.
Web GUI: Configuration > Link OAM > Events Settings
Figure 4-171: Detailed Link OAM Statistics for selected port
Table 4-163: Detailed Link OAM Statistics for selected port Parameters
Receive Total and Transmit Total
Rx and Tx OAM
Information PDU's
Rx and Tx Unique
Error Event
Notification
238
The number of received and transmitted OAM Information PDU's.
Discontinuities of this counter can occur at re-initialization of the
management system.
A count of the number of unique Event OAMPDUs received and
transmitted on this interface. Event Notifications may be sent in
duplicate to increase the probability of successfully being received, given
the possibility that a frame may be lost in transit. Duplicate Event
Notification transmissions are counted by Duplicate Event Notification
counters for Tx and Rx respectively. A unique Event Notification
OAMPDU is indicated as an Event Notification OAMPDU with a Sequence
Number field that is distinct from the previously transmitted Event
Notification OAMPDU Sequence Number.