Page 2
Document version Date Proprietary Information. This document contains information, which is proprietary to Fibrolan Ltd. No part of its contents may be used, copied, disclosed or conveyed to a third party in any manner whatsoever without prior written permission from Fibrolan Ltd.
µFalcon-MX/G must first be installed and connected to a GNSS antenna (for details on antenna installation refer to Technical Note: GPS/GNSS Antenna Installation Guidelines on www.fibrolan.com Resources webpage). 1 Physical Description The M Class Falcon /G models are high-performance Carrier Ethernet switches, which includes highly comprehensive Timing and Synchronization capabilities.
Before starting with the Timing configuration ensure proper management access via web GUI. Detailed information on system turnup can be found in the Falcon M class Getting Started quick guide that can be found in www.fibrolan.com. 2.2 GPS/GNSS Signal Additional prerequisite is to assure a proper satellite signal. To do that hit the GPS/GNSS port on the front panel at the GUI home page.
T e c h N o t e : P T P G r a n d m a s t e r C o n f i g u r a t i o n 3 PTP Configuration 3.1 G.8275.1 Profile This Precision time protocol telecom profile is intended for phase/time synchronization with full timing support network.
Page 6
T e c h N o t e : P T P G r a n d m a s t e r C o n f i g u r a t i o n • Apply the configuration by pressing the Apply at the bottom of the page. 3.2 G.8275.2 Profile This Precision time protocol telecom profile is intended for phase/time synchronization with partial timing support network.
Page 7
T e c h N o t e : P T P G r a n d m a s t e r C o n f i g u r a t i o n • Apply the configuration by pressing the Apply at the bottom of the page. 3.3 G.8265.1 Profile This Precision time protocol telecom profile is intended for frequency synchronization.
Page 8
T e c h N o t e : P T P G r a n d m a s t e r C o n f i g u r a t i o n • Apply the configuration by pressing the Apply at the bottom of the page. •...