Toshiba e-STUDIO2008A Service Manual page 504

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

* c. Separation roller
Apply an even coat of grease (Alvania No.2) to all round the inside of the spring.
When replacing the separation roller, apply adequate amount of white grease (Molykote HP-300)
on the places of the holder shown in the figure (4 places).
Notes:
Make sure that the grease does not adhere to the roller surface. Wipe it off with alcohol if
adhered.
Apply grease on the inner surface
Fig. 7-10
* e. Registration roller (Pusher)
Apply 2 rice-sized grains of white grease (Molykote EM-30L) to the 2 contact points of the
registration roller (rubber) and the pusher.
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
PREVENTIVE MAINTENANCE (PM)
Apply white grease
Registration roller
Grease
Pusher
Fig. 7-12
© 2015 TOSHIBA TEC CORPORATION All rights reserved
7 - 20
Fig. 7-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents