6.9
Scanner
6.9.1
Adjustment carriages-1 positions
(1)
Take off the RADF/DSDF.
 P. 4-171 "4.13.2 MR-3031 (Reversing
Automatic Document Feeder)"
(2)
Take off the right top cover.
 P. 4-4 "4.1.8 Right top cover"
(3)
Take off the original glass.
 P. 4-18 "4.3.1 Original glass"
(4)
Take off the left top cover.
 P. 4-3 "4.1.5 Left top cover"
(5)
Move the carriage-1[1] toward the exit side.
Notes:
Rotate the drive pulley to move the carriage.
(6)
Loosen the 2 fixing screws of the wire.
Tighten the screws by aligning the sections
[5] and [6] of the carriage-1 with the inside of
the exit side frame [2].
Notes:
Confirm that they are aligned properly
through the windows [3] and [4] of the exit
side frame [2].