Parts to be replaced
Transfer roller
[E510] ADU stack jam (paper not reaching the ADU entrance sensor)
Classification
Paper transport jam (ADU section) Jam not reaching the ADU entrance sensor
Proce
Check item
dure
1
Open the ADU. Is there
any paper in front of the
ADU entrance sensor?
2
Is the ADU entrance
sensor working? (Perform
the input check in the test
mode: 03-[FAX]OFF/[1]/
[D])
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Error content
Result
Yes
Remove the paper.
No
Yes
No
Check if the connector of the ADU entrance
sensor is disconnected.
Check if the connector CN311 on the LGC
board is disconnected.
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor patterns on the MOT
board and LGC board are short circuited or
open circuited. (e-STUDIO206L/256/306 /
207L/257/307)
Check if the conductor patterns on the
MOT2 board and LGC board are short
circuited or open circuited.
(e-STUDIO356/456/506 / 357/457/507)
Replace the ADU entrance sensor.
Replace the LGC board.
8 - 75
Remark
Measure
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
Next
Step
2
3
8