Toshiba e-STUDIO2008A Service Manual page 398

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

6.3.4
Scanner related adjustment
[A] Image distortion
A
Step 1
C
Step 2
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
Press [TEST COPY]  [START] to make a copy of any image on a sheet of A3/LD paper.
(2)
(3)
Key in [3033] and press the [START] button to move the carriage to the adjustment position.
(4)
Make an adjustment in the order of step 1 and 2.
Step 1
In case of A:
Tighten the mirror-3 adjustment screw (Rear) [1]
(CW).
In case of B:
Loosen the mirror-3 adjustment screw (Rear) [1]
(CCW).
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
Feeding direction
Feeding direction
Fig.6-9
© 2015 TOSHIBA TEC CORPORATION All rights reserved
6 - 14
B
D
Fig.6-10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents