Notes:
Be sure to attach the belt [10] when carrying
out installation.
Notes:
When replacing both the transport roller
and the collar, or performing machine
refreshment, apply an appropriate
amount of white grease (Molykote EM-
30L) inside of the collars [11]. When
applying the grease, make sure that the
grease is not running over.
Grease might run out before the machine
refreshment depending on frequency of
use, apply an appropriate amount of
grease as necessary.
4.12.14 Reverse sensor (S18) <35ppm/45ppm/50ppm>
(1)
Remove the ADU middle cover.
 P. 4-155 "4.12.5 ADU middle cover
<35ppm/45ppm/50ppm>"
(2)
Release the latch and take off the reverse
sensor [1].
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
DISASSEMBLY AND REPLACEMENT
© 2015 TOSHIBA TEC CORPORATION All rights reserved
4 - 164
Fig. 4-439
[11]
Fig. 4-440
Fig. 4-441