Proce
Check item
dure
3
Is the exit motor (rotating
in reverse) working?
(Perform the output check
in the test mode: 03-121/
171): e-STUDIO206L/256/
306 / 207L/257/307
(Perform the output check
in the test mode: 03-124/
174): e-STUDIO356/456/
506 / e-STUDIO357/457/
507
4
ADU
Parts to be replaced
ADU entrance sensor
LGC board
Exit motor
ADU exit sensor
Exit board
LGC board
Rollers in the ADU
Exit roller
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
Result
Yes
No
•
Check if the connector of the exit motor is
disconnected.
•
Check if the connector CN431 on the MOT
board is disconnected.
(e-STUDIO206L/256/306 / 207L/257/307)
•
Check if the connector CN405 on the MOT2
board is disconnected.
(e-STUDIO356/456/506 / 357/457/507)
•
Check if the connector pins are
disconnected and the harnesses are open
circuited.
•
Check if the conductor pattern on the LGC
board and MOT board is short circuited or
open circuited. (e-STUDIO206L/256/306 /
207L/257/307)
•
Check if the conductor pattern on the LGC
board and MOT2 board is short circuited or
open circuited. (e-STUDIO356/456/506 /
357/457/507)
•
Replace the exit motor.
•
Replace the MOT board. (e-STUDIO206L/
256/356 / 207L/257/357)
•
Replace the MOT2 board. (e-STUDIO356/
456/506 / 357/457/507)
•
Replace the LGC board.
•
Check the rollers in the ADU and the exit
roller of the equipment. Replace them if
they are worn out.
© 2015 TOSHIBA TEC CORPORATION All rights reserved
8 - 76
Measure
Remark
Next
Step
4