[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [TEST COPY]
button, immediately after starting the 05 Adjustment Mode, single-sided test copying can be performed
(normal copy mode).
<Operation keys>
FS
05
POWER
1
Digital keys
: Key in codes.
START
Digital keys
: Key in adjustment
values.
( CLEAR Use to make corrections)
Value ZZZ is stored
OK
replacing values YYY.
TEST COPY
Test copy
START
If the test copy does not
satisfy the specified values,
return to step 1 and
repeat the adjustment
procedure.
Power OFF/ON : Exit the Adjustment Mode.
© 2015 TOSHIBA TEC CORPORATION All rights reserved
<Display>
100%
A
A3
TEST MODE
Code No.
100%
XXX
A3
TEST MODE
YYY
Current adjustment value
100%
A
A3
TEST MODE
100%
A
A3
Wait Warming Up
100%
A
A3
COPYING
Fig.6-6
6 - 5
Adjustment value newly keyed in.
ZZZ
(If no entering, YYY is displayed.)
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT