When the power is turned ON or the LCF drawer is inserted (when the power is turned ON or
equipment drawer / PFP drawers are inserted), LCF (PFP/equipment) performs initialization.
Detects the presence of paper
Tray-up motor ON – The tray goes up
At this time, the tray-up sensor and empty sensor are OFF.
When the tray-up sensor is not turned ON in a fixed period of time, it means that
the tray is in abnormal condition.
 "Add paper" is displayed regardless of presence/absence of paper.
 Cleared by turning the drawer open/close
 Tray-up sensor is turned ON in a fixed period of time.
-
The tray motor stops.
At this time, if the empty sensor is ON:
When the paper in the drawer runs out during copying,
 The tray-up sensor turned OFF
 The tray-up motor turned ON
The tray-up sensor turned ON
Empty sensor turned OFF during the copying in spite of the tray-up sensor is ON
Drawer area of the LCD panel blinks (When the drawer is selected)
(B) Pick-up failure in bypass (
During bypass feeding
Bypass feed clutch ON
1st transport sensor is not turned ON in a fixed period of time
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
OUTLINE OF THE MACHINE
Drawer area of the LCD panel blinks (When the drawer is selected)
It is judged that there is no paper.
The copying operation is stopped.
)
3 - 24
It is judged that there is paper.
OFF: It is judged that there is no paper.
Tray goes up
Tray-up motor stopped.