[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
Performs FS-05.  (05 Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
Press [TEST COPY]  [START] to make a copy at the mode of A3 (LD), 100% and the lower
(3)
drawer (Refer to *).
(4)
Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
FS-05  Key in the code [3032]  [START]
 (Key in a value (acceptable values: 63 to 193))
 Press the [OK] button (stored in memory).
 ("100% A" is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes. (approx.
0.018%/step)