[D] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
Performs FS-05. (05 Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
Press [TEST COPY] [START] to make a copy at the mode of A3 (LD), 100% and the lower
(3)
drawer (Refer to *).
(4)
Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(5)
Check if the distance C is within the range of 200±0.5 mm.
(6)
If not, use the following procedure to change values and repeat steps (3) to (5) above.
FS-05 Key in the code [3032] [START]
(Key in a value (acceptable values: 63 to 193))
Press the [OK] button (stored in memory).
("100% A" is displayed.)
* The smaller the adjustment value is, the lower the reproduction ratio becomes. (approx.
0.018%/step)
50
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT
Copied image of the ruler
100
150
200
Fig.6-14
6 - 18
250
300
350
C
Feeding direction
© 2015 TOSHIBA TEC CORPORATION All rights reserved
400