4.12.11 ADU entrance sensor (S7)
(1)
Remove the ADU guide assembly.
<35ppm/45ppm/50ppm>
 P. 4-152 "4.12.3 ADU guide assembly
<35ppm/45ppm/50ppm>"
<20ppm/25ppm/30ppm>
 P. 4-154 "4.12.4 ADU guide assembly
<20ppm/25ppm/30ppm>"
(2)
Disconnect 1 connector [2] from the ADU
guide assembly [1].
(3)
Release the latch and remove the ADU
entrance sensor [3].
4.12.12 ADU exit sensor (S6)
(1)
Remove the ADU guide assembly.
<35ppm/45ppm/50ppm>
 P. 4-152 "4.12.3 ADU guide assembly
<35ppm/45ppm/50ppm>"
<20ppm/25ppm/30ppm>
 P. 4-154 "4.12.4 ADU guide assembly
<20ppm/25ppm/30ppm>"
(2)
Disconnect 1 connector [2] from the ADU
guide assembly [1].
(3)
Release the latch and remove the ADU exit
sensor [3].
4.12.13 Transport roller (Upper and lower)
(1)
Remove the ADU guide assembly.
<35ppm/45ppm/50ppm>
 P. 4-152 "4.12.3 ADU guide assembly
<35ppm/45ppm/50ppm>"
<20ppm/25ppm/30ppm>
 P. 4-154 "4.12.4 ADU guide assembly
<20ppm/25ppm/30ppm>"
(2)
Bend the rib [2] of the ADU guide assembly
[1] to remove the collar [3].