Toshiba e-STUDIO2008A Service Manual page 329

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

5.5
[04 TEST PRINT MODE]
The embedded test pattern can be printed out.
<Operation procedure>
[FS]
(Code)
[04]
Notes:
When an error occurs, it is indicated on the panel, but the recovery operation is not performed.
Turn OFF the power and then back ON to clear the error.
During test printing, the [CLEAR] button is disabled when "Wait adding toner" is displayed.
Refer to the "Self-diagnostic code list" (separate document) for the codes available in the [04
TEST PRINT MODE].
© 2015 TOSHIBA TEC CORPORATION All rights reserved
(Media selection)
[START]
5 - 11
Operation
[CLEAR]
Continuous
Test Printing
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SELF-DIAGNOSTIC MODE
[POWER]
OFF/ON
(Exit)
5