6.4.7
Gamma balance adjustment
The density can be adjusted by regulating the gamma balance. The adjustment can be performed by
selecting its density area from the following: low density, medium density and high density.
Language and screen
Text/
Photo
Text
Photo
7190-0
7192-0
7191-0
7190-1
7192-1
7191-1
7190-2
7192-2
7191-2
Notes:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
(1)
Performs FS-05.
(2)
Key in the code for an item to be adjusted and then press the [START] button.
(3)
Key in a number for the density area to be adjusted (0, 1 or 2), and then press the [START]
button.
0: Low density 1: Medium density 2: High density
(4)
Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(5)
Press the [OK] button to store the value in memory. The equipment goes back to the ready state.
(6)
For resetting the value, repeat step (2) to (5).
(7)
Press the [TEST COPY] button and then the [START] button. Then perform test copying.
(8)
If the desired image density has not been attained, repeat step (2) to (7).
© 2015 TOSHIBA TEC CORPORATION All rights reserved
Item to be adjusted
User
custom
7276-0
Low density
7276-1
Medium density
7276-2
High density
6 - 27
< 05 Adjustment Mode >
Remarks
The larger the value is, the density
of the item to be adjusted becomes
darker.
Acceptable values: 0 to 255.
(Default: 128)
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
SETTING / ADJUSTMENT