Toshiba e-STUDIO2008A Service Manual page 750

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO2008A:
Table of Contents

Advertisement

Probable cause
Hole punch control PC board (HP)
abnormality
[CC60] Punch motor (M15) abnormality
MJ-1033
Error
Punch motor
Punch shaft home position sensor
Punch motor clock sensor
Probable cause
Punch motor (M15) abnormality
Punch shaft home position sensor
(S36) abnormality
Punch shaft rotational direction
sensor (S35) abnormality
Punch motor clock sensor (S37)
abnormality
Faulty cables and connectors
Hole punch control PC board (HP)
abnormality
[CC61] Punch motor (M3) home position detection error
MJ-1101/1106 (When MJ-6103 is installed), MJ-1107/1108 (When MJ-6104 is installed)
* The [CC61] error occurs when the [E9F0] error occurs three times in succession or during the initial
operation.
Classification
Finisher related service call
Check Item
Transport path
e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
Checking and measures
If the error still occurs after replacing the motor, sensors and
connectors, exchange the hole punch control PC board (HP).
Timing of detection
The status of the punch motor clock sensor (S36) is not
changed for the specified time when the punch motor (M15) is
driven.
The number of input pulses of the punch motor clock sensor
(S36) does not fall within the range from 70 to 100 in the OFF
period of the punch shaft home position sensor (S35), or is
larger than 30 in the ON period of the punch shaft home
position sensor (S35).
Checking and measures
Check if the electrical continuity of the coil is normal. If
electricity is not conducted, replace the motor.
Measure the voltage on pin CN3.3 on the hole punch control
PC board (HP). Then check that the measured voltage is 1V or
lower when not shielded and within the range of 5V5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Measure the voltage on pin CN3.9 on the hole punch control
PC board (HP). Then check that the measured voltage is 1V or
lower when not shielded and within the range of 5V5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Measure the voltage on pin CN3.6 on the hole punch control
PC board (HP). Then check that the measured voltage is 1V or
lower when not shielded and within the range of 5V5% when
shielded. If the voltage does not fall within the range mentioned,
replace the sensor.
Check if the electrical continuity between the connector
terminals is normal. If electricity is not conducted, replace the
connector. (Hole punch control PC board (HP): CN3, CN6)
If the error still occurs after replacing the motor, sensors and
connectors, exchange the hole punch control PC board (HP).
Punch motor (M3) home position detection error: Punch motor
is not rotating or puncher is not shifting normally.
If there is any paper remaining on the transport path, remove
the paper.
© 2015 TOSHIBA TEC CORPORATION All rights reserved
8 - 212
Contents
Measure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents